S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
22-285
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 22 Show Commands
show module
6 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 active *
7 48 1/2/4 Gbps FC Module DS-X9148 ok
9 16 1/2 Gbps FC Module DS-X9016 powered-dn
Mod Power-Status Power Down Reason
--- ------------ ---------------------------
9 powered-dn Insufficient resources (dest Index)
switch#
show port index-allocation
Module index distribution:
------------------------------------------------------+
Slot | Allowed | Alloted indices info |
| range* | Total | Index values |
-----|---------|-------|------------------------------|
1 | 0- 31| 48 | 160-187,192-207,220-223 | (Slot 2 shares 28-31)
| | |(Slot 3 shares 16-27) (Slot 7 shares 0-15)|
2 | 32- 63| 48 | 28-63,240-251 |
3 | 64- 95| 48 | 16-27,64-95,188-191 |
4 | 96- 127| 48 | 96-127,224-239 |
7 | 128- 159| 48 | 0-15,128-159 |
8 | 160- 191| - | (None) | (Slot 1 shares 160-187
| | |) (Slot 3 shares 188-191) |
9 | 192- 223| - | (None) | (Slot 1 shares 192-207
| | |,220-223) |
SUP | 253-255 | 3 | 253-255 |
*Allowed range applicable only for Generation-1 modules
switch#
show module 9 recovery-steps
Failure Reason:
Insufficient indices in range 0-255. Module cannot be powered up
The following example uses the show port index-allocation command on the Cisco MDS 9124 switch.
switch#
show port index-allocation
Module index distribution:
------------------------------------------------------+
Slot | Allowed | Allotted indices info |
| range* | Total | Index values |
-----|---------|-------|------------------------------|
1 | 0- 255| 24 | 0-23 |
SUP | ----- | - | (None) |
*Allowed range applicable only for Generation-1 modules
The following example uses the
show module
,
show port index-allocation
, and
show module
recovery-steps
commands to display a Generation 1 module that is powered down because indices are
not available in its slot. Specifically, indices 28 through 31 are taken by a 48-port card in slot 2.
switch#
show module
Mod Ports Module-Type Model
Status
--- ----- -------------------------------- ------------------ --
1 32 1/2 Gbps FC Module powered-dn
2 48 1/2/4 Gbps FC Module DS-X9148 ok
4 48 1/2/4 Gbps FC Module DS-X9148 ok
6 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 active *
Mod Power-Status Power Down Reason
--- ------------ ---------------------------
1 powered-dn Insufficient resources (dest Index)
switch#
show port index-allocation