![Cisco MDS 9000 Series Command Reference Manual Download Page 1159](http://html.mh-extra.com/html/cisco/mds-9000-series/mds-9000-series_command-reference-manual_212531159.webp)
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
22-91
Cisco MDS 9000 Family Command Reference
OL-18089-01, Cisco MDS NX-OS Release 4.x
Chapter 22 Show Commands
show fc2
b294a7c0 3 0 1410 65535 0 0 0
b294a480 2 7 1410 65535 0 0 0
b294a140 3 0 1409 262142 0 0 0
b278bb20 3 0 1409 262142 0 0 0
b278b4a0 3 0 1407 65535 0 0 0
b278b160 3 0 1407 256000 0 0 0
b278ae20 3 0 1407 65535 0 0 0
b1435b00 3 0 1408 65535 0 0 0
b1434e00 3 0 1406 65535 0 0 0
b1434ac0 3 0 1406 131072 0 0 0
b1434780 3 0 1406 65535 0 0 0
b1434440 2 0 1405 131072 0 0 0
b1434100 3 0 1405 262142 0 0 b1434440
b22e2420 2 0 1372 65535 0 0 0
...
The following example displays FC2 socket binding information:
switch#
show fc2 bind
SOCKET RULE SINDEX VSAN D_ID MASK TYPE SUBTYPE M_VALUES
b23ba0c0 16 6081000 1 0 0 0 00:00:00 00:00:00:00:00:00:00:00
b2a647e0 7 ffffffff 65535 fffffd ffffff 22 03:01:00 14:15:16:00:00:00:00:00
b294b180 7 ffffffff 65535 fffffd ffffff 1 02:01:00 61:62:00:00:00:00:00:00
b294ae40 7 ffffffff 65535 fffc00 ffff00 22 01:01:00 1b:00:00:00:00:00:00:00
b294a7c0 7 ffffffff 65535 fffffd ffffff 1 01:01:00 10:00:00:00:00:00:00:00
...
The following example displays FC2 local N port information:
switch#
show fc2 nport
REF VSAN D_ID MASK FL ST IFINDEX CF TC 2-SO IC RC RS CS
EE 3-SO IC RC RS CS EE
1 65535 fffffd ffffff 3 0 ffffffff c800 0128 8000 0000 0000 2112 0064 0
008 8000 0000 0000 2112 0064 0000
6 65535 fffc00 ffff00 18b 0 ffffffff c800 0128 8000 0000 0000 2112 0064 0
008 8000 0000 0000 2112 0064 0000
2 65535 fffffa ffffff 3 0 ffffffff c800 0128 8000 0000 0000 2112 0064 0
008 8000 0000 0000 2112 0064 0000
1 65535 fffffc ffffff 3 0 ffffffff c800 0128 8000 0000 0000 2112 0064 0
008 8000 0000 0000 2112 0064 0000
...
The following example displays FC2 PLOGI session information:
switch#
show fc2 plogi
HIX ADDRESS VSAN S_ID D_ID IFINDEX FL STATE CF TC 2-SO IC RC
RS CS EE 3-SO IC RC RS CS EE EECNT TCCNT 2CNT 3CNT REFCNT
2157 af364064 1 fffc6c 123400 ffffffff 0000 0 0000 0001 8000 0000 2000
0256 0001 0001 8000 0000 2000 0256 0001 0000 0 0 0 0 1
The following example displays FC2 physical port information:
switch#
show fc2 port
IX ST MODE EMUL TXPKTS TXDROP TXERR RXPKTS RXDROP R_A_TOV E_D_TOV
F-SO RC RS CS EE 2-SO RS 3-SO RS
0 D 1 0 0 0 0 0 0 10000 2000
8000 0000 2112 0001 0001 8000 0256 8000 0256
1 D 1 0 0 0 0 0 0 10000 2000
8000 0000 2112 0001 0001 8000 0256 8000 0256
2 D 1 0 0 0 0 0 0 10000 2000
8000 0000 2112 0001 0001 8000 0256 8000 0256
3 D 1 0 0 0 0 0 0 10000 2000
8000 0000 2112 0001 0001 8000 0256 8000 0256
4 D 1 0 0 0 0 0 0 10000 2000
8000 0000 2112 0001 0001 8000 0256 8000 0256