1-11
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Chapter 1 Introducing the Sensor
Appliances
Output is directed to the serial port. Use the no display-serial command to
redirect output to the keyboard/monitor.
Note
You can set up a terminal server and use the IDS CLI display-serial
command to direct all output from the appliance to the serial port.
This option enables you to view system messages on a console
connected to the serial port, even during the boot process. When you
use this option, all output is directed to the serial port and any local
keyboard/monitor connection is disabled. However, BIOS and POST
messages are still displayed on the local keyboard/monitor.
Note
There is only one console port on an IDS-4215, IPS-4240, and
IPS-4255; therefore, the display-serial and no display-serial
commands do not apply to those platforms.
Step 3
Be sure to properly close a terminal session to avoid unauthorized access to the
appliance.
If a terminal session is not stopped properly, that is, if it does not receive an exit(0)
signal from the application that initiated the session, the terminal session can
remain open. When terminal sessions are not stopped properly, authentication is
not performed on the next session that is opened on the serial port.
Tip
Always exit your session and return to a login prompt before terminating
the application used to establish the connection.
Caution
If a connection is dropped or terminated by accident, you should reestablish the
connection and exit normally to prevent unauthorized access to the appliance.