8-5
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Chapter 8 Installing the IDSM-2
Installation and Removal Instructions
Shutdown Button
To prevent corruption of the IDSM-2, you must use the shutdown command to
shut it down properly. See Step 1 of
Removing the IDSM-2, page 8-13
, for
instructions on properly shutting down the IDSM-2. If the IDSM-2 does not
respond, firmly press the Shutdown button on the faceplate and wait for the Status
indicator to turn amber. The shutdown procedure may take several minutes.
Caution
Do not remove the IDSM-2 from the switch until the module shuts down
completely. Removing the module without going through a shutdown procedure
can corrupt the application partition on your module and result in data loss.
Installation and Removal Instructions
All Catalyst 6500 series switches support hot swapping, which lets you install,
remove, replace, and rearrange modules without turning off the system power to
the switch. When the system detects that a module has been installed or removed,
it runs diagnostic and discovery routines, acknowledges the presence or absence
of the module, and resumes system operation with no operator intervention.
Caution
You must first shut down the IDSM-2 before removing it from a Catalyst 6500
series switch. See
Removing the IDSM-2, page 8-13
, for the procedure for
removing an IDSM-2 from a Catalyst 6500 series switch.
This section contains the following topics:
•
Required Tools, page 8-6
•
Slot Assignments, page 8-6
•
Installing the IDSM-2, page 8-7
•
Removing the IDSM-2, page 8-13
Summary of Contents for IDS-4230-FE - Intrusion Detection Sys Fast Ethernet Sensor
Page 4: ......
Page 450: ...Appendix B Troubleshooting ...