Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Chapter 10 Configuring the Sensor Using the CLI
NM-CIDS Configuration Tasks
Step 6
Exit interface mode:
Router(config-if)# exit
Step 7
Repeat Steps 3 though 6 for each interface or subinterface that you want to
monitor.
Step 8
Exit configuration mode:
Router(config)# exit
Step 9
Verify that the NM-CIDS is analyzing network traffic.
a.
Open a TFTP or SSH session to the external interface on the NM-CIDS.
Note
SSH requires known hosts. See
Adding Known Hosts to the SSH
Known Hosts List, page 10-19
, for the procedure.
b.
Log in as cisco.
c.
View the interface group:
Router# show interface group 0
d.
If the output shows the sensing interface is down, repeat Steps 3 through 6.
e.
Repeat Step c to see the counters gradually increasing. This indicates that the
NM-CIDS is receiving network traffic.
Checking the Status of the Cisco IDS Software
To check the status of the Cisco IDS software running on the router:
Router# service-module ids-sensor slot_number/0 status
Something similar to the following output appears:
Router# service-module ids-sensor1/0 status
Service Module is Cisco IDS-Sensor1/0
Service Module supports session via TTY line 33
Service Module is in Steady state
Getting status from the Service Module, please wait..
Service Module Version information received,
Major ver = 1, Minor ver= 1