Chapter 5 Installing the IDS-4235 and IDS-4250
Installing the Accessories
5-40
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Figure 5-13 Rotating the Front-Mounting Bracket for Flush-Mount Installation
Step 7
Repeat Steps 4 though 6 to configure the other slide assembly.
Step 8
Holding the left slide assembly into position in the two-post rack at the location
you marked, adjust the extended rear bracket tightly against the back of the
vertical two-post rack and secure it to the two-post rail with two 12-24 x 0.5-inch
pan-head Phillips screws (see
Figure 5-14 on page 5-41
).
Step 9
Secure the front bracket on the slide assembly to the two-post rail with two 12-24
x 0.5-inch pan-head Phillips screws (see
Figure 5-14 on page 5-41
).
Step 10
Repeat Steps 8 and 9 to install the right slide assembly in the rack.
Step 11
Use and 11/32-inch wrench or nut driver to fully tighten the nuts on the mounting
brackets on both slide assemblies that you tightened with your fingers.
78107