Chapter 10 Configuring the Sensor Using the CLI
Reimaging Appliances and Modules
10-128
Cisco Intrusion Detection System Appliance and Module Installation and Configuration Guide Version 4.1
78-15597-02
Step 3
Enter configuration mode:
sensor# configure terminal
Step 4
Reimage the maintenance partition:
sensor# upgrade
ftp://
user@ftp_server_IP_address/directory_path/image_file
You are asked whether you want continue.
Step 5
Type y to continue.
The maintenance partition file is upgraded.
Cisco IOS Software
To reimage the maintenance partition, follow these steps:
Step 1
Obtain the maintenance partition file from Software Center on Cisco.com and
copy it to an SCP or FTP server.
See
Obtaining Cisco IDS Software, page 9-1
, for instructions on how to access the
Software Center on Cisco.com.
Step 2
Log in to the switch CLI.
Step 3
Session in to the application partition CLI:
cat6k# session slot
slot_number
processor 1
Step 4
Enter configuration mode:
cat6k# configure terminal
Step 5
Reimage the maintenance partition:
cat6k(config)# upgrade
ftp://
user@ftp_server_IP_address
/
directory_path
/
image_file