NVF5 Series User Manual
Chapter 6 Parameter Function Description
same time
,
the inverter will stop.
K1
K2
RUN
0
0
0
1
1
0
1
1
STOP
Run
Reverse
Run
Forward
STOP
+24V
PLC
DI1
DI2
COM
K1
K2
Figure 6-1-1 Two Wire Control Mode1
Parameters Setting as below
:
Code
Name
Values
Description
F0.01
Command Channel
Selection
1
Terminal Control
F5.08
Terminal Control
Mode Selection
0
Two Wire Control
Mode1
F5.01
DI1
Function
Selection
1
Forward
(
FWD
)
F5.02
DI2
Function
Selection
2
Reverse
(
REV
)
Two Wire Control Mode 2
:
In this mode
,
DI1 is Run Enable input terminal
,
DI2 control the direction.Shown in the
below figure
,
in this mode when K1 is closed
,
K2 is opened,the inverter will run forward
,
K2 is closed the inverter will run reverse
;
when K1 is opened
,
the inverter will stop.
K1
K2
RUN
0
0
0
1
1
0
1
1
STOP
STOP
Run
Forward
Run
Reverse
+24V
PLC
DI1
DI2
COM
K1
K2
Figure 6-1-2 Two Wire Control Mode2
Parameters Setting as below
:
Code
Name
Values
Description
F0.01
Command Channel
Selection
1
Terminal Control
- 39 -