NVF5 Series User Manual Chapter 6 Parameter Function Description
F0.08
Digital Given
50.00Hz
F0.09
~
F0.07
-
F0.09
Digital Given
0.00Hz
0.00 Hz
~
F0.08
-
F0.13
(UP/DN)
Regulation
Control
0x0000
0x0000
~
0x1111
Ones Place
:
After Speed
Setting by Integral
Keypad(UP/DN)
0
:
Frequency
setting non
storage
when power off
1
:
Frequency
setting storage when
power off
Tens Place
:
After Speed
Setting by Integral
Keypad(UP/DN)
0
:
Frequency
maintain when stop
1
:
Frequency restet
to initial when stop
Hundreds Place
:
After
Speed Setting by Digital
Terminals(UP/DN)
0
:
Frequency
setting non storage when
power off
1
:
Frequency setting
6.2.3
Analog Main Frequency Setting
(
AI1
、
AI2 setting
)
Setting main frequency reference by AI1
、
AI2
,
there are 4 kinds of different AI curves
for each AI channel
,
See below setting progress
:
Setting Procedure
Parameter
Description
(
Step1
)
Set AI as
frequency source
:
Select AI
channel according to AI
channel specification
F0.02
Main Frequency Source
Selection
:
F0.02=1
:
AI1 as main frequency
souce
F0.02=2
:
AI2 as main frequency
souce
(
Step2
)
AI Curve selection
:
Select suitable AI curve
F5.24
AI Curve Selection
(
Step3
)
AI curve setting
modes
:
F5.25
~
F5.28
Curve 1Setting
F5.29
~
F5.32
Curve 2Setting
- 43 -