Precautions during operation
9-6-1. Change in settings during operation
When changing the settings during operation any of the settings except partial setting screen can be changed.
When settings cannot be changed during operation, error message is displayed during setting change
operation. However changing the settings during control operation by using parameter, may adversely affect the
control, hence take care.
An example, when a step was changed during execution is given below, please refer to it.
①
When SV1 is changed
An example where in SV1 (setting value) of step n is changed to SV2 is given. In case of this example,
please understand that there was a setting value operation in step n+1 before change, however there is no
setting value operation in step n+1 after change.
②
When TIME is changed
An example wherein TIME (required time) of step n is changed just a little by T is given. On a whole
there is a shift of only T minutes.
SV2
SV1
Pattern before
change
Pattern after
change
Change point
Step n
Step n + 1
Step n + 2
Step n after change
Step n +1 after change
SV
T
Pattern before change
Pattern after
change
Change point
Step n before change
T
Step n+1 before change