- 65 -
9.
・
SV section of PID number 9 is out of scope.
・
Confirm the SV section and do the settings again.
10.
・
L is exceeding H.
・
Confirm L/H and do the settings again.
11.
・
Z is exceeding S.
・
Confirm Z/S and do the settings again.
12.
・
Linear range is exceeding the scope of measurement
range.
・
Confirm the measurement range and do the settings again.
13.
・
F.B. tuning is not starting as the status is not RESET status.
・
Start F.B. tuning after making the status as RESET.
14.
・
As pattern selection system or program drive system has
selected exterior, operation cannot be done by front key.
・
When doing the operation by front key, change the pattern
selection system.
15.
・
Operation cannot be started as there is an error in step
repetition setting.
・
Start the operation after reconfirming the settings.
16.
・
Control algorism is not changed because of program
operating.
・
Change the control algorism after stopping the program
operating.
17.
・
Time is not changing as status is not RESET status.
・
Change the time after changing the status to RESET.