- 115 -
11-15-3. Precaution about setting
Item of precaution
Description
1. Precaution of SV value of
program pattern
・
Rage of SV of program pattern is the rage which is set at
[measurement range] of mode5 or [linear scale].
・
When SV is over the above range during program operation, it is
limited by higher limit value (or lower limit value).
2. Precaution of setting range
of SV range
・
[SV range] is the setting range of only SV of SV start.
SV during program operation is within the rage of [measurement
range] of mode 5 or [liner scale].
3. When set [time000:00] by
program pattern
・
Gradient value is changed momentary to next step’s gradient value
by changing the setting of [time000:00] at executing parameter of
mode 0.
In this case, program operation of next step is started from SV which
is changed setting to [time000:00].
・
When set the program pattern at mode 2, setting of [time000:00] is
possible for changing the gradient value of the next step momentary.
Setting of [time000:00] on the continuous setting is possible,
however when program pattern, which is set [time 000:00] after
many connections of the step, is run, correct control operation is not
performed and get trouble in system, so do not like the above.
・
In step of [time000:00], operation is only changing set gradient value
momentary.
Therefore, each calculations (PID, alarm, sensor
correction etc.) are not performed.
However, setting content is effective in step of [time000:00]. For
example, when set [time000:00] in step No. 03 and set alarm No. 4
in same step and set alarm No. 0 in step No. 4 which is next step,
alarm of the step No.04 is operated in alarm No.04.
・
In setp of [time000:00], real temperature compensation and time
signal is not operated.
When want to operate these function, set
more than [time000:01].
11-15-4. Precaution of operation
Operation Description
1. ADV (advance)
・
When performed ADV operation, program operation is continued
from top of the stepping.
SV which is started program operation from stepping become SV
that the gradient vale which is set stepping is passed duration time.