1 Operational Manual
This menu provides users to check the output signal from CDC-2000, when the code
number turns to red, it means this output signal is
“
ON
”
. The descriptions are as
below:
No. Content
Description
60
Close pneumatic door When the pneumatic door is closing, this signal will “ON”.
61
Open pneumatic door When the pneumatic door is opening, this signal will “ON”.
62
Nozzle Forward
Carriage Forward Output
63
Injection Injection
Output
64
Feeding
Plasticizing Output
65
Decompression Decompression
Output
66
Nozzle Backward
Carriage Backward Output
67
Mold Open / Close
Output
Mold Open /Close Output
68
Ejector Forward
Ejector Forward Output
69
Ejector Backward
Ejector Backward Output
04/08/13