1 Operational Manual
O) XXX.X: Decompression stroke setup for feeding.
2.20.9 Time Setup:
A) dddd.d: Time setup for cooling.
B) eeee.e: Time setup for recycle.
C) ffff.f:Time setup for alarm-cycle
2.21 Temperature Setup
TEMPERATURE SETTING PAGE MOLD NO : yyyyyyyy
NOZZLE T1 T2 T3 T4 T5 T6 Tc
OIL. T ??? ℃ AA% BBB CCC DDD EEE FFF GGG HHH
??? ??? ??? ??? ??? ??? ???
HIGH ALARM III JJJ KKK LLL MMM NNN OOO
LOW ALARM PPP QQQ RRR SSS TTT UUU VVV
AIR COOLING aaa bbb ccc ddd eee fff
SELECT ZZZZZZZZZZZ
IN SATND-BY TEMPERATURE MODE, DROP SETTING TEMPERATURE : YY%
FREQUENT USING RESINS BARREL TEMPERATURE
RESIN T1 T2 T3 T4 T5 T6 TC DENSITY
PE 260 270 260 255 250 240 500 1.0
PP 220 230 220 210 200 190 500 1.0
HI-PS 210 220 210 200 190 180 500 1.0
ABS 255 260 250 240 230 220 500 1.0
PC 280 300 290 280 270 260 500 1.0
PA-66 300 300 290 280 270 260 500 1.0
POM 200 210 210 200 190 180 500 1.0
PMMA-1 240 250 240 230 220 210 500 1.0
PMMA-2 225 230 220 210 210 200 500 1.0
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Menu 20
Move the cursor to set parameter. Key in desired digits and press
to complete a correction.
Code descriptions for menu 20 are listed below
2.21.1 Code of temperature setup are listed below:
A) AA: Set percentage value of nozzle heating.
B) BBB: T1 temperature set value.
C) CCC: T2 temperature set value.
D) DDD: T3 temperature set value.
E) EEE: T4 temperature set value.
04/08/13