CDC-2000
操作手冊
Operational Manual
B) Fast-speed cylinder mold-opening as the 2
nd
step to quickly open the molds.
Either the standard mold-opening method or the hydraulic pressure loop
differentiated method can be applied in this step. If you choose the hydraulic
pressure loop differentiated method, please move to
“
Function selection
”
for
“
super fast mold-opening will speed up.
”
However, parameter
“
MM
”
has to be set
above 70% to execute this function.
C) Fast-speed cylinder decelerated mold-opening as the 3
rd
step.
2.5.3.8 Special Function Setup
The setup for function selection: move the cursor to “
j
” “
k
”and “
l
”, press either
or
for “open “or ”close “
.
Code descriptions for function selection are as follows:
D) j:Function selection for fast-speed cylinder fast mold-opening.
E) k:Spare function selection.
F) l:Function selection for mold opening and closing of fast-speed cylinder
special mold. Code descriptions for parameters of the special mold are as follows:
F.a) WWWW.W :Mold-closing start-position setup for fast-speed cylinder special
mold.
F.b) ZZZ.Z :The moving distance setup for mold closing of fast-speed cylinder
special mold.
F.c) XX :Mold-closing speed setup for fast-speed cylinder special mold.
F.d) YY :Mold-closing pressure setup for fast-speed cylinder special mold.
F.e) aaaa.a :Mold-opening start-position setup for fast-speed cylinder special
mold.
F.f) ddd.d :The moving distance setup for mold opening of fast-speed cylinder
special mold.
F.g) bb :Mold-opening speed setup for fast-speed cylinder special mold.
F.h) cc :Mold-opening pressure setup for fast-speed cylinder special mold.
04/08/13