1 Operational Manual
3.20 “035 Too Many Bad Products.”
(A) Numbers of defect part exceed the setting values on menu 43
“
CC.C%
”
.
(B) Remedy:
a) Reset the standard and deviation in menu 44.
b) Re-modify the parameter of injection.
c) Select
“
close
”
at
“
MMMMMMMM
”
of menu 43.
PRODUCT COUNTR PAGE
GOOD NO. DEFECT NO. PRODUCT NO. DEFECT %
SET NO. AAAAA + BBBBB = CC.C%
TOTAL NO. FFFFF GGGGG HHHHHH II.I%
SELECT LLLLLLLL MMMMMMMM
BATCH NO. NO OF DEFECTS.
SET NO. DDDDD EEEEE
TOTAL NO. JJJJJ KKKKK
SELECT NNNNNNNN OOOOOOOO
WORKING HOUR : PPPPP HR QQ MIN
AUTO. RUNNING HOUT : RRRRR HR SS MIN
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Menu 43
0
3.21 “036 Check Core pull 2 through the Limit Switch”
(A) Conditions:
a) Core out 2 L.S. did not activate in stroke check time.
b) Core out L.S. (Input 07) and core in L.S.(Input06) is on simultaneously.
c) Core out L.S. (Input 07) is not on (OFF) while intending to do ejector forward.
(B)Remedy:
a) Check the circuit of Input 06 and Input 07.
04/08/13