1 Operational Manual
05/02/03
202
(B)
To operate printer move cursor to selecting switch
“
M
”
, press
or
to select
“
open
”
, then printer can be used.
(C)
In the automatic operation, after cyclic operation, printer will print data
referred to parameter.
4.4.3 The Printing Format:
Column
Descripti
on.
Perfect
No.
Defect
No.
Product
cycle
Filling
time
Injec-
tion end
Feeding
time
Feeding
end
V/P
Pres.
T1 T2 T3 T4 T5 T6 TC
4.4.4 Manual
Printing
In manual mode, press
and
simultaneously, the printer will print the
current displaying manual, and will appear the printer
‘
s mark in the lower left
corner and show the percentage of printing in the lower right corner, at the same
time, CDC-2000 may pause until the printing operation is finished.
Menu 44
LL=1
Menu 44
LL=5
65503 65530 65.4 2.65 10.2 9.0 105.3 62 199 210 200 191 32 32 32
65504 65530 65.2 2.61 10.5 9.6 105.1 60 200 210 200 191 32 32 32
65505 65530 64.9 2.62 10.4 9.3 105.4 61 200 211 199 190 32 32 32
. . . . . . . . . . . . . . .
65505 65530 65.4 2.65 10.2 9.0 105.3 62 199 210 200 191 32 32 32
65510 65530 65.2 2.61 10.5 9.6 105.1 60 200 210 200 191 32 32 32
65515 65530 64.9 2.62 10.4 9.3 105.4 61 200 211 199 190 32 32 32
. . . . . . . . . . . . . . .