1 Operational Manual
05/02/03
190
alarm will sound.
(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify TC deviation settings in menu 20.
3.68
“ 109 The Practical Oil Temperature Is Too Low “
(A) When hydraulic oil temperature is lower than setting value, warning message will
appear.
(B) Remedy: If warning message comes up, check
“
liquid pressure temperature
”
function.
3.69
“ 110 The Practical Oil Temperature Is Too High at Sector 1 “
(A)If the actual barrel temperature is higher than the computer setting temperature
plus the high temperature deviation in menu 20, the alarm will show. The injection
operation can be done in auto mode, but the plasticizing and decompression can
not. There is no limitation in manual mode.
(B)Remedy:
a)
Please check whether the heater junction is short-circuited.
b)
Please adjust the T1 temperature deviation in menu 20.
TEMPERATURE SETTING PAGE MOLD NO : yyyyyyyy
NOZZLE T1 T2 T3 T4 T5 T6 Tc
OIL. T ??? ℃ AA% BBB CCC DDD EEE FFF GGG HHH
??? ??? ??? ??? ??? ??? ???
HIGH ALARM III JJJ KKK LLL MMM NNN OOO
LOW ALARM PPP QQQ RRR SSS TTT UUU VVV
AIR COOLING aaa bbb ccc ddd eee fff
SELECT ZZZZZZZZZZZ
IN SATND-BY TEMPERATURE MODE, DROP SETTING TEMPERATURE : YY%
FREQUENT USING RESINS BARREL TEMPERATURE
RESIN T1 T2 T3 T4 T5 T6 TC DENSITY
PE 260 270 260 255 250 240 500 1.0
PP 220 230 220 210 200 190 500 1.0
HI-PS 210 220 210 200 190 180 500 1.0
ABS 255 260 250 240 230 220 500 1.0
PC 280 300 290 280 270 260 500 1.0
PA-66 300 300 290 280 270 260 500 1.0
POM 200 210 210 200 190 180 500 1.0
PMMA-1 240 250 240 230 220 210 500 1.0
PMMA-2 225 230 220 210 210 200 500 1.0
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Menu20