1 Operational Manual
05/02/03
184
MOLD OPEN AND CLOSE SETTING
????.?
mm
?????
p
FAST LOW-PR. HI-PR.
SPEED % AA DD GG FORCE
PRESSURE % BB EE HH
TTT TONS
TIME SEC vvv.v
POSTION mm CCC.C FFFFFp
IIIIIp
BACK-PR. % ee ff gg
hhh.h iii.i
TO SLOW FAST SLOW
PP MM JJ SPEED %
QQ NN KK
PRESSURE %
RRR.R OOO.O LLLLLp
POSTION mm
UU TT SS
BACK-PR. %
BOOST CLAMPING : j SPARE FUNCTION : k
TRIPLE PLATEN MODE : l
START POS. STORKE SPEED PRESSURE
CLAMPING WWWW.W ZZZ.Z XX YY
MOLD OPEN aaaa.a ddd.d bb cc
Menu03
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
3.51
“079 Error of Ejection Advance”
(A)Ejector forward did not complete in stroke check time at auto mode.
(B)Remedy:
a)
Check parameters
“
AA
”
,
“
BB
”
,
“
CCC.C
”
,
“
DD
”
,
“
EE
”
,
“
FFF.F
”
in menu 05.
b)
Check ejector mechanism.
c)
Check/modify time setting (Tim 39B) in menu 39B.