1 Operational Manual
05/02/03
186
TIMER REVIEW MONITORING PAGE 2
DESCRIPTION SET TURE DESCRIPTION SET TURE
SPARE T32 AAAA.A ????.? SPARE T33 BBBB.B ????.?
SPARE T34 CCCC.C ????.? SPARE T35 DDDD.D ????.?
ABNOR MD OP DELAY EEEE.E ????.? SPARE T37 FFFF.F ????.?
COUNT MD THICK
GGGG.G
????.? NOZZLE STROKE CHEC
HHHH.H
????.?
SPARE T40
IIII.I
????.? SPARE T41
JJJ.JJ
???.??
SPARE T42
KKKK.K
????.? SPARE T43
LLLL.L
????.?
EJECT BUFFER TIME
MMM.MM
???.?? ABNORMAL SHUT-OFF
NNNN.N
????.?
ATUO CLA END BUF
OOOO.O
????.? AUTO OP END BUF TI
PPPP.P
????.?
MOTOR START-UP
QQQ.QQ
???.?? SPARE T49
RRRR.R
????.?
DECOM END DELAY
SSS.SS
???.?? CLAMP END. DELAY
TTTT.T
????.?
SPECIAL FUNC
UUU.UU
????.? CLAMP CYL. DELAY
VVV.VV
???.??
SPARE T54
WWWW.W
????.? CLA CYL.O. DELAY
XXXX.X
????.?
Q.M.CYL.O DELAY
YYY.YY
???.?? MOLD OPEN TIME
ZZZ.ZZ
???.??
M.THICK DELAY
aaa.aa
???.?? UNSCREW END DELAY
bbb.bb
???.?
FEEDING END DELAY
ccc.cc
???.?? SPARE T61
ddd.dd
???.??
CORE END DELAY
eee.ee
???.?? 1 SEC TIMER
fff.ff
???.??
Menu39B
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
3.52
“080 Restart the Safe Door”
After one cycle at semi-auto mode, this message will show up.
Remedy: open front door, take part out, and close it again.
3.53
“090 Temperature Sensor Breakdown at Sector 1”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace first section thermocouple.
b)
Check/replace first section MC and heater.
3.54
“091 Temperature Sensor Breakdown at Sector 2”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy: