7.4.2 Remote Digital Loopback
This test checks the local DTE, the local modem, the remote modem, and
the telephone line. It can be used with, or without, the modem's self-test
feature.
1. Ensure that your modem has established a connection with a remote
modem.
2. If required, set the test timer with the command
ATS18=n
(
n
= 1 to 255
seconds).
3. Ensure that the remote modem is conditioned to accept an RDL test
(
&T4
).
4. Enter the command
AT&T6
(without self-test) or
AT&T7
(with self-test)
and press
ENTER
.
5. If you selected
&T6
(without self-test), you must transmit a test message.
This should be echoed back via the remote modem's digital loopback
connection.
If you selected
&T7
(with self-test), the test sequence is automatic and
the circuit is checked for errors. Errors may be injected with the
command
AT&T99
.
6. To terminate the test manually, enter the command
AT&T0
and press
RETURN
. The modem responds with the message
OK
.
If you had selected the self-test feature, the error count is also displayed.
If the call is disconnected during the test, the test procedure is terminated.
X450-310851 Issue 2
7-7
Rev.0
Summary of Contents for syncro 1496
Page 10: ...X450 310851 Issue 2 0 10 Rev 1...
Page 12: ...X450 310851 Issue 2 1 2 Rev 0...
Page 20: ...X450 310851 Issue 2 1 10 Rev 0...
Page 28: ...X450 310851 Issue 2 2 8 Rev 0...
Page 36: ...X450 310851 Issue 2 3 8 Rev 0...
Page 38: ...X450 310851 Issue 2 4 2 Rev 0...
Page 76: ...X450 310851 Issue 2 5 10 Rev 0...
Page 102: ...X450 310851 Issue 2 7 16 Rev 0...
Page 130: ...X450 310851 Issue 2 8 28 Rev 0...
Page 134: ...X450 310851 Issue 2 9 4 Rev 0...
Page 144: ...X450 310851 Issue 2 A 4 Rev 0...
Page 178: ...X450 310851 Issue 2 C 30 Rev 0...
Page 179: ...X450 310851 Issue 2 C 31 Rev 0...
Page 182: ...X450 310851 Issue 2 C 34 Rev 0...