COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3–238
3. OPERATIONS AND TIMING
J. *7* ACC (accessory mode)
•
Use this mode to adjust/operate options.
•
Each press on the
key brings up the next screen; each press on the
key, on the other
hand, brings up the previous screen.
•
Press the item to adjust/operate to that it becomes highlighted.
•
Use the keypad to enter numerals.
•
A press on the
key will permanently store the value.
•
After operation, turn off and then on the rear main power switch.
1. Adjusting the Original Stop Position for the RDF
•
This screen is effective only when an RDF is installed.
CANCEL
+
OK
*7* ACC 01
DOC_ST_T
: (+xx) <- (+xx)
P_INTRVL_T
: (+xx) <- (+xx)
DOC_ST_B
: (+xx) <- (+xx)
P_INTRVL_B
: (+xx) <- (+xx)
–
Item
DOC_ST_T
P_INTRVL_T
DOC_ST_B
P_INTRVL_B
Function
Use it to adjust the origi-
nal stop position for upper
separation pick-up.
Use it to adjust the origi-
nal stop position for upper
separation pick-up in 2-on-
1 mode.
Use it to adjust the origi-
nal stop position for lower
separation pick-up.
Use it to adjust the origi-
nal stop position for lower
separation pick-up in 2-on-
1 mode.
Description
OK