C. Flow of Image Signals
1. Flow of Image Signals from the Printer Board
The PDL data from the host computer is processed into printing images on the Printer Board and sent
to the Protocol Controller PCB as image signals.
The image signals move through the Protocol Controller PCB to reach the CORE/IP Board. After res-
olution conversion, the image signals move to the Image processor PCB for printing.
CCD
Shading
correction
Image processor PCB
Reproduction
ratio
Edge
emphasis
Reversal
Synthesis
Density
correction
Binary
processing
(PD)
D/A
conversion
Laser
SCSI board
Density
correction
Expansion
memory
Memory
Memory
memory
controller
Rotation
Smoothing
SCSI
control
Host
computer
Resolution
conversion/
repoduction
ratio
Binary
processing
(ED)
CIST
CORE/IP Board
FAX Board
NCU
Telephone
line
Rotation
Coding/
decoding
modem
Memory
Protocol Controller Board
Command
conversion
Video
controller
I/F
controller
Printer Board
LAN
controller
DP
RAM
DP
RAM
Host
computer
LAN
NIB
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3–154
3. OPERATIONS AND TIMING