3–199
COPYRIGHT © 1996 CANON INC. CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
3. Back-Up Data for the Composite Power Supply PCB
CANCEL
+
OK
*3* ADJUST 03
AGS GAIN
: xxxxx <– (xxxxx)
AGS OFST
: xxxxx <– (xxxxx)
PRI DC OFST : xxxxx <– (xxxxx)
PRI AC OFST1 : xxxxx <– (xxxxx)
PRI AC OFST2 : xxxxx <– (xxxxx)
TRNS OFFST : xxxxx <– (xxxxx)
FL OFST
: xxxxx <– (xxxxx)
DEV DC OFST : xxxxx <– (xxxxx)
–
Item
AGS GAIN
AGS OFST
PRI DC
OFST
PRI AC
OFST1
PRI AC
OFST2
TRSN
OFFST
FL OFST
DEV DC
OFST
Description
Indicate APVC gain.
Indicates APVC offset.
Indicates primary charging DC offset.
Indicate primary charging AC offset 1.
Indicates primary charging AC offset
2.
Indicates transfer charging offset.
Indicates scanning lamp offset.
Indicates developing bias DC compo-
nent offset.
Remarks
If you have
replaced the com-
posite power supply
PCB, be sure to
enter the value
recorded on the
label attached to
the composite
power supply PCB.
(see P3-160)
Settings
0~255
Label*
APVC GAIN
APVC OFST
PDC OFST
PAC OFST1
PAC OFST2
ATVC OFST
FL OFST
DDC OFST
* Service Label; attached to the composite power supply PCB.