1. General
- 9 -
Item
40G COMPACT
Remarks
Drop Not
applicable
Water-proofing Not
applicable
Resistance to chemicals
Not applicable
IC X-ray protection
No protective lead
Back-scattering prevention
Not considered
Imaging unit installation
*The imaging unit can be installed to a
Bucky unit, stand or table.
*The imaging unit can be installed without
modification to the Liebel-Flarsheim
Bucky unit and compatible Bucky units.
Imaging unit securing
components are obtained
from the respective dealer.
The attachment of the
imaging unit uses M5 screw
holes (10 locations) in the
imaging unit.
Grid
*Fixed grid
*Installation inside imaging unit is not
possible
*Installed in a Bucky unit, stand or table.
*Same specifications as 40EG grid
Grid and the grid securing
components are obtained
from the respective dealer.
Grid attachment/removal
Can be performed by service staff only.
Cannot be performed by users.
Phototimer
*Installation inside imaging unit is not
possible
*Installed in a Bucky unit, stand or table.
*Except for the external dimensions, the
specifications are identical to the 40EG
phototimer
Phototimer and the
phototimer securing
components are obtained
from the respective dealer.
Calibration
Can be performed by service staff only.
Cannot be performed by users.
Users can conduct a
self-diagnostic test.
Environmental friendliness
(RoHS supported)
Supported
Compatible control PC
*FC-E21A for CXDI Control Station
*General-purpose PC with same
performance as FC-E21A
Compatible operating system
Windows XP SP3 (or SP2)
Power ON/OFF control
None
Stand
Dedicated stand, table or universal stand
Connectability
*Up to four units can be connected to a
single control PC (using a hub)
*Up to three identical imaging units are
possible
*Imaging unit and power box are paired
X-ray exposure delay
Less than 0.3 sec.
Exposure preparation time
Normal exposure mode: 10 sec.
Long time exposure mode: 30 sec.
Full image preview time
Approx. 12 sec.
Exposure cycle time
15 sec. or less in normal exposure mode
System control unit
Control PC, power box
Summary of Contents for CXDI-40G COMPACT
Page 24: ...2 Installation 4 2 CXDI SYSTEM III Assembly Packaging Accessories Box Power Box ...
Page 56: ...2 Installation 36 8 3 When Timeout due to RX_REQ not Negating ...
Page 135: ...2 Installation 115 16 2 Power Box Mass 4 2 Kg not including cable Unit mm ...
Page 136: ...2 Installation 116 16 3 Ready Lamp Unit Mass 0 5 Kg Unit mm ...