F. Secondary Transfer Roller
1) Open the ITB unit drawer.
2) Shift the secondary transfer roller
removal lever toward you.
3) Holding the gear, slide the secondary
transfer roller to the right to remove.
➀
Secondary transfer roller removal lever
➁
Gear
➂
Secondary transfer roller
Figure 3-4-7
< Note for reassembly >
When installing a new secondary transfer
roller, make sure not to touch the sponge
area of the roller.
Figure 3-4-8
G. Upper Thermoswitch
1) Unhook the 2 claws and remove the fix-
ing cover 1.
➀
Claws
➁
Fixing cover 1
Figure 3-4-9
2) Remove the 3 screws and then the
upper thermoswitch.
➀
Screws
➁
Upper thermoswitch
Figure 3-4-10
3 - 24
CHAPTER 3
➁
➀
➂
Shaft
Shaft
Sponge
➁
➀
➀
➁
➀