Code
Description
Arg 1
Arg 2
Arg 3
Arg 4
Config
Lock
If Config Lock = Yes, an active configuration lock in the Scanner prevents changes to the register.
500700 Obtains wireless
mesh path
information for all
connected motes.
—
—
—
—
No
501000 Clears statistic
information for a
target port.
0 = All
1 = Serial Port 1
2 = Serial Port 2
3 = Serial Port 3
21 = TCP 1
22 = TCP 2
—
—
—
No
600000 Triggers the creation
of a snapshot file.
0 = All
1 = Flow Run 1
2 = Flow Run 2
—
—
—
No
600300 Stores the current
Flow Run Factor
Calibration Map Data
as a new calibration.
Web interface should
be used to configure
the calibration type.
New factors must be
written (per the Linear
Calibration Factor
procedure below)
before sending this
command.
1 = Flow Run 1
2 = Flow Run 2
—
—
—
Yes
600302 Stores the current
Input K-Factor
Calibration Map Data
as a new calibration.
Web interface should
be used to configure
the calibration type.
New factors must be
written (per the Linear
Calibration Factor
procedure below)
before sending this
command.
1 = Pulse Input 1
2 = Pulse Input 2
3 = Pulse Input 3
—
—
—
Yes
601000 Programs the
operating mode for
a PID controller. The
analog output must
be in PID mode for
this command to take
effect.
1 = Analog Output 1
2 = Analog Output 2
0 = Automatic
1 = Manual Override
—
—
No
13
Scanner 3100 Modbus Protocol
Section 1