Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9441
24E1
Slave Device 18: Holding: Analog Input 1
Instantaneous Reading
FP
V
RO
9442
24E2
Slave Device 18: Holding: Analog Input 2
Instantaneous Reading
FP
V
RO
Slave 19 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9451
24EB
Slave Device 19: Holding: Update Date
FP
MMDDYY
RO
9452
24EC
Slave Device 19: Holding: Update Time
FP
HHMMSS
RO
9453
24ED
Slave Device 19: Holding: Flow Run Volume Daily
Total
FP
MCF
RO
9454
24EE
Slave Device 19: Holding: Flow Run Volume Flow
Rate
FP
MCF/day
RO
9455
24EF
Slave Device 19: Holding: Flow Run Mass Daily
Total
FP
lbm
RO
9456
24F0
Slave Device 19: Holding: Flow Run Mass Flow
Rate
FP
lbm/day
RO
9457
24F1
Slave Device 19: Holding: Flow Run Energy Daily
Total
FP
Btu
RO
9458
24F2
Slave Device 19: Holding: Flow Run Energy Flow
Rate
FP
Btu/day
RO
9459
24F3
Slave Device 19: Holding: T1 Volume Daily Total
FP
bbl
RO
9460
24F4
Slave Device 19: Holding: T1 Volume Flow Rate
FP
bbl/day
RO
9461
24F5
Slave Device 19: Holding: T2 Volume Daily Total
FP
bbl
RO
9462
24F6
Slave Device 19: Holding: T2 Volume Flow Rate
FP
bbl/day
RO
9463
24F7
Slave Device 19: Holding: Static Pressure
Instantaneous Reading
FP
psig
RO
9464
24F8
Slave Device 19: Holding: Differential Pressure
Instantaneous Reading
FP
"H2O@68°F
RO
9465
24F9
Slave Device 19: Holding: RTD Instantaneous
Reading
FP
°F
RO
9466
24FA
Slave Device 19: Holding: Analog Input 1
Instantaneous Reading
FP
V
RO
9467
24FB
Slave Device 19: Holding: Analog Input 2
Instantaneous Reading
FP
V
RO
Slave 20 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9476
2504
Slave Device 20: Holding: Update Date
FP
MMDDYY
RO
9477
2505
Slave Device 20: Holding: Update Time
FP
HHMMSS
RO
9478
2506
Slave Device 20: Holding: Flow Run Volume Daily
Total
FP
MCF
RO
78
Section 1
Scanner 3100 Modbus Protocol