Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7482
1D3A
FR1: HFluid: Ideal Absolute Viscosity
FP
lbm/ft•s
RO
7483
1D3B
FR1: HFluid: Molar Mass
FP
kg/kg•mol
RO
7484
1D3C
FR1: HFluid: Fuel H to C Ratio
FP
—
RO
7485
1D3D
FR1: HFluid: Base Temperature
FP
°F
RO
7486
1D3E
FR1: HFluid: Base Pressure Absolute
FP
psia
RO
7487
1D3F
FR1: HFluid: Gas Base Density
FP
lbm/ft³
RO
7488
1D40
FR1: HFluid: Gas Base Viscosity
FP
lbm/ft•s
RO
7489
1D41
FR1: HFluid: Gas Base Molar Density
FP
kg•mol/m³
RO
7490
1D42
FR1: HFluid: Gas Base Compressibility Factor
FP
—
RO
7491
1D43
FR1: HFluid: Flowing Temperature
FP
°F
RO
7492
1D44
FR1: HFluid: Flowing Pressure Absolute
FP
psia
RO
7493
1D45
FR1: HFluid: Gas Flowing Density
FP
lbm/ft³
RO
7494
1D46
FR1: HFluid: Gas Flowing Viscosity
FP
lbm/ft•s
RO
7495
1D47
FR1: HFluid: Gas Flowing Molar Density
FP
kg•mol/m³
RO
7496
1D48
FR1: HFluid: Gas Flowing Compressibility Factor
FP
—
RO
7497
1D49
FR1: HFluid: Air Density
FP
lbm/ft³
RO
7498
1D4A
FR1: HFluid: Air Molar Density
FP
kg•mol/m³
RO
7499
1D4B
FR1: HFluid: Combustion Reference Temperature
FP
°F
RO
7500
1D4C
FR1: HFluid: Molar Combustion Heating Value 25 C
FP
MMBtu/lb•mol
RO
7501
1D4D
FR1: HFluid: Molar Combustion Heating Value
FP
MMBtu/lb•mol
RO
7502
1D4E
FR1: HFluid: Mass Combustion Heating Value
FP
MMBtu/lbm
RO
7503
1D4F
FR1: HFluid: Gross Volume Combustion Heating Value
FP
MMBtu/ft³
RO
7504
1D50
FR1: HFluid: User Mass Combustion Heating Value
FP
MMBtu/lbm
RO
7505
1D51
FR1: HFluid: User Gross Volume Combustion Heating
Value
FP
MMBtu/ft³
RO
7506
1D52
FR1: HFluid: Vapor Pressure Of Water
FP
psia
RO
7507
1D53
FR1: HFluid: Net Volume Combustion Heating Value
FP
MMBtu/ft³
RO
7508
1D54
FR1: HFluid: Wobbe Index
FP
—
RO
7509
1D55
FR1: HFluid: Motor Octane Number Linear
FP
—
RO
7510
1D56
FR1: HFluid: Motor Octane Number CARB
FP
—
RO
7511
1D57
FR1: HFluid: Methane Number Linear
FP
—
RO
7512
1D58
FR1: HFluid: Methane Number CARB
FP
—
RO
7513
1D59
FR1: HFluid: Heat Of Vaporization Of Water
FP
Btu
RO
7514
1D5A
FR1: HFluid: Enthalpy Change Of Vapor Water
FP
Btu
RO
7515
1D5B
FR1: HFluid: Enthalpy Change Of Liquid Water
FP
Btu
RO
7516
1D5C
FR1: HFluid: Isentropic Exponent
FP
—
RO
7517
1D5D
FR1: HFluid: Joule Thompson Coefficient
FP
—
RO
7518
1D5E
FR1: HFluid: Enthalpy Composite
FP
MMBtu/lbm
RO
7519
1D5F
FR1: HFluid: Gross CH Pseudocomponent
FP
—
RO
7520
1D60
FR1: HFluid: Gross Carbon Dioxide
FP
—
RO
48
Section 1