Input/Output Configuration (Integers)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5601
15E0
Differential Pressure: Configure: Override Enable
INT32
—
RW
5602
15E1
Static Pressure: Configure: Override Enable
INT32
—
RW
5603
15E2
RTD1: Configure: Override Enable
INT32
—
RW
5604
15E3
RTD2: Configure: Override Enable
INT32
—
RW
5605
15E4
Analog 1: Configure: Override Enable
INT32
—
RW
5606
15E5
Analog 2: Configure: Override Enable
INT32
—
RW
5607
15E6
Analog 3: Configure: Override Enable
INT32
—
RW
5608
15E7
Analog 4: Configure: Override Enable
INT32
—
RW
5609
15E8
Pulse Input 1: Configure: Override Enable
INT32
—
RW
5610
15EA
Pulse Input 2: Configure: Override Enable
INT32
—
RW
5611
15EB
Pulse Input 3: Configure: Override Enable
INT32
—
RW
5612
15EC
Analog Output 1 PID: Configure: Override Enable
INT32
—
RW
5613
15ED
Analog Output 2 PID: Configure: Override Enable
INT32
—
RW
Flow Run 1 Configuration (Integers)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5701
1645
Flow Run 1: Config: Flow Direction
INT32
—
RW
5702
1646
Flow Run 1: CFlow: Meter Tube Material
INT32
—
RW
5703
1647
Flow Run 1: CFlow: Orifice Material
INT32
—
RW
5704
1648
Flow Run 1: CFlow: Tap Type
INT32
—
RW
5705
1649
Flow Run 1: CFlow: Tap Location
INT32
—
RW
Flow Run 2 Configuration (Integers)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5801
16A9
Flow Run 2: Config: Flow Direction
INT32
—
RW
5802
16AA
Flow Run 2: CFlow: Meter Tube Material
INT32
—
RW
5803
16AB
Flow Run 2: CFlow: Orifice Material
INT32
—
RW
5804
16AC
Flow Run 2: CFlow: Tap Type
INT32
—
RW
5805
16AD
Flow Run 2: CFlow: Tap Location
INT32
—
RW
To decode meter tube material, orifice material, tap type, and tap location, refer to
Flow Run 2 Holding (Integers), page 29
To decode flow direction, refer to
.
34
Section 1
Scanner 3100 Modbus Protocol