Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9233
2411
Slave Device 10: Holding: Flow Run Energy Flow
Rate
FP
Btu/day
RO
9234
2412
Slave Device 10: Holding: T1 Volume Daily Total
FP
bbl
RO
9235
2413
Slave Device 10: Holding: T1 Volume Flow Rate
FP
bbl/day
RO
9236
2414
Slave Device 10: Holding: T2 Volume Daily Total
FP
bbl
RO
9237
2415
Slave Device 10: Holding: T2 Volume Flow Rate
FP
bbl/day
RO
9238
2416
Slave Device 10: Holding: Static Pressure
Instantaneous Reading
FP
psig
RO
9239
2417
Slave Device 10: Holding: Differential Pressure
Instantaneous Reading
FP
"H2O@68°F
RO
9240
2418
Slave Device 10: Holding: RTD Instantaneous
Reading
FP
°F
RO
9241
2419
Slave Device 10: Holding: Analog Input 1
Instantaneous Reading
FP
V
RO
9242
241A
Slave Device 10: Holding: Analog Input 2
Instantaneous Reading
FP
V
RO
Slave 11 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9251
2423
Slave Device 11: Holding: Update Date
FP
MMDDYY
RO
9252
2424
Slave Device 11: Holding: Update Time
FP
HHMMSS
RO
9253
2425
Slave Device 11: Holding: Flow Run Volume Daily
Total
FP
MCF
RO
9254
2426
Slave Device 11: Holding: Flow Run Volume Flow
Rate
FP
MCF/day
RO
9255
2427
Slave Device 11: Holding: Flow Run Mass Daily
Total
FP
lbm
RO
9256
2428
Slave Device 11: Holding: Flow Run Mass Flow
Rate
FP
lbm/day
RO
9257
2429
Slave Device 11: Holding: Flow Run Energy Daily
Total
FP
Btu
RO
9258
242A
Slave Device 11: Holding: Flow Run Energy Flow
Rate
FP
Btu/day
RO
9259
242B
Slave Device 11: Holding: T1 Volume Daily Total
FP
bbl
RO
9260
242C
Slave Device 11: Holding: T1 Volume Flow Rate
FP
bbl/day
RO
9261
242D
Slave Device 11: Holding: T2 Volume Daily Total
FP
bbl
RO
9262
242E
Slave Device 11: Holding: T2 Volume Flow Rate
FP
bbl/day
RO
9263
242F
Slave Device 11: Holding: Static Pressure
Instantaneous Reading
FP
psig
RO
9264
2430
Slave Device 11: Holding: Differential Pressure
Instantaneous Reading
FP
"H2O@68°F
RO
9265
2431
Slave Device 11: Holding: RTD Instantaneous
Reading
FP
°F
RO
72
Section 1
Scanner 3100 Modbus Protocol