Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9077
2375
SD2: Holding: Differential Pressure Instantaneous
Reading
FP
"H2O@68°F
RO
9079
2377
SD2: Holding: RTD Instantaneous Reading
FP
°F
RO
9081
2379
SD2: Holding: Analog Input 1 Instantaneous
Reading
FP
V
RO
9083
237B
SD2: Holding: Analog Input 2 Instantaneous
Reading
FP
V
RO
Slave 3 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9101
238D
SD3: Holding: Update Date
FP
MMDDYY
RO
9103
238F
SD3: Holding: Update Time
FP
HHMMSS
RO
9105
2391
SD3: Holding: Flow Run Volume Daily Total
FP
MCF
RO
9107
2393
SD3: Holding: Flow Run Volume Flow Rate
FP
MCF/day
RO
9109
2395
SD3: Holding: Flow Run Mass Daily Total
FP
lbm
RO
9111
2397
SD3: Holding: Flow Run Mass Flow Rate
FP
lbm/day
RO
9113
2399
SD3: Holding: Flow Run Energy Daily Total
FP
Btu
RO
9115
239B
SD3: Holding: Flow Run Energy Flow Rate
FP
Btu/day
RO
9117
239D
SD3: Holding: T1 Volume Daily Total
FP
bbl
RO
9119
239F
SD3: Holding: T1 Volume Flow Rate
FP
bbl/day
RO
9121
23A1
SD3: Holding: T2 Volume Daily Total
FP
bbl
RO
9123
23A3
SD3: Holding: T2 Volume Flow Rate
FP
bbl/day
RO
9125
23A5
SD3: Holding: Static Pressure Instantaneous
Reading
FP
psig
RO
9127
23A7
SD3: Holding: Differential Pressure Instantaneous
Reading
FP
"H2O@68°F
RO
9129
23A9
SD3: Holding: RTD Instantaneous Reading
FP
°F
RO
9131
23AB
SD3: Holding: Analog Input 1 Instantaneous
Reading
FP
V
RO
9133
23AD
SD3: Holding: Analog Input 2 Instantaneous
Reading
FP
V
RO
Slave 4 Holding (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9151
23BF
SD4: Holding: Update Date
FP
MMDDYY
RO
9153
23C1
SD4: Holding: Update Time
FP
HHMMSS
RO
9155
23C3
SD4: Holding: Flow Run Volume Daily Total
FP
MCF
RO
9157
23C5
SD4: Holding: Flow Run Volume Flow Rate
FP
MCF/day
RO
9159
23C7
SD4: Holding: Flow Run Mass Daily Total
FP
lbm
RO
9161
23C9
SD4: Holding: Flow Run Mass Flow Rate
FP
lbm/day
RO
180
Section 2
Scanner 3100 Modbus Protocol