Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5312
14C0
Flow Run 1: HFlow: Tap Type
INT32
—
RO
5313
14C1
Flow Run 1: HFlow: Tap Location
INT32
—
RO
Flow Run 2 Holding (Integers)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5401
1519
Flow Run 2: Config: Calculation Period
INT32
—
RW
5402
151A
Flow Run 2: Config: Fluid Calculation Interval
INT32
—
RW
5403
151B
Flow Run 2: Config: Dampening Mode
INT32
—
RW
5404
151C
Flow Run 2: HAccum: Flow Direction
INT32
—
RO
5405
151D
Flow Run 2: HFluid: Method
INT32
—
RO
5406
151E
Flow Run 2: HFluid: Override
INT32
—
RO
5407
151F
Flow Run 2: HFlow: Method
INT32
—
RO
5408
1520
Flow Run 2: HFlow: Override
INT32
—
RO
5409
1521
Flow Run 2: HFlow: Installation Parameters
INT32
—
RO
5410
1522
Flow Run 2: HFlow: Meter Tube Material
INT32
—
RO
5411
1523
Flow Run 2: HFlow: Orifice Material
INT32
—
RO
5412
1524
Flow Run 2: HFlow: Tap Type
INT32
—
RO
5413
1525
Flow Run 2: HFlow: Tap Location
INT32
—
RO
Flow Direction
Bit Position
Description
0
Accumulating flow from positive differential
pressure or positive uncorrected accumulation
1
Accumulating flow from negative differential
pressure or negative uncorrected accumulation
Fluid Information Methods
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
LV2
LV1
LV0
DS1
DS0
AL2
AL1
AL0
—
SR2
SR1
SR0
SPC
—
TAS
TST
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
—
HC2
HC1
HC0
ITE
—
F02
F01
F00
E04
E03
E02
E01
E00
Value
F02-F00: Fluid Type
0
Gas Mixture
1
Gas Gross
2
Fluid Pure Substance
3
Liquid Hydrocarbon Mixture
4
Liquid Gross
5
Liquid Composite
29
Scanner 3100 Modbus Protocol