Slave 11 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9751
2617
Slave Device 11: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
9752
2618
Slave Device 11: Flow Run Config: Carbon Dioxide
FP
—
RW
9753
2619
Slave Device 11: Flow Run Config: Nitrogen
FP
—
RW
9754
261A
Slave Device 11: Flow Run Config: Specific Gravity
FP
—
RW
9755
261B
Slave Device 11: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
9756
261C
Slave Device 11: Flow Run Config: Oil Density
FP
lbm/ft³
RW
9757
261D
Slave Device 11: Flow Run Config: Gas Fraction
FP
—
RW
9758
261E
Slave Device 11: Flow Run Config: Plate Diameter
FP
inch
RW
9759
261F
Slave Device 11: Flow Run Config: Pipe Diameter
FP
inch
RW
9760
2620
Slave Device 11: Flow Run Config: Cone Beta
FP
—
RW
9761
2621
Slave Device 11: Flow Run Config: Nominal Value
FP
—
RW
9762
2622
Slave Device 11: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
9763
2623
Slave Device 11: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 12 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9776
2630
Slave Device 12: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
9777
2631
Slave Device 12: Flow Run Config: Carbon Dioxide
FP
—
RW
9778
2632
Slave Device 12: Flow Run Config: Nitrogen
FP
—
RW
9779
2633
Slave Device 12: Flow Run Config: Specific Gravity
FP
—
RW
9780
2634
Slave Device 12: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
9781
2635
Slave Device 12: Flow Run Config: Oil Density
FP
lbm/ft³
RW
9782
2636
Slave Device 12: Flow Run Config: Gas Fraction
FP
—
RW
9783
2637
Slave Device 12: Flow Run Config: Plate Diameter
FP
inch
RW
9784
2638
Slave Device 12: Flow Run Config: Pipe Diameter
FP
inch
RW
9785
2639
Slave Device 12: Flow Run Config: Cone Beta
FP
—
RW
9786
263A
Slave Device 12: Flow Run Config: Nominal Value
FP
—
RW
9787
263B
Slave Device 12: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
9788
263C
Slave Device 12: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 13 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9801
2649
Slave Device 13: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
9802
264A
Slave Device 13: Flow Run Config: Carbon Dioxide
FP
—
RW
84
Section 1
Scanner 3100 Modbus Protocol