Code
Description
Arg 1
Arg 2
Arg 3
Arg 4
Config
Lock
If Config Lock = Yes, an active configuration lock in the Scanner prevents changes to the register.
120000 Sets the internal real-
time clock
RealDate
(0xYYYYMMDD)
RealTime
(0xHHMMSS00)
—
—
No
0x00000000 =
Preserve Current Date
TIME = 0x00000000:
Preserve Current
Time
TIME = 0x00000001:
Set RTC to 00:00:00
—
—
No
120001 Sets the date of the
internal real-time
clock.
Year = Gregorian year
in decimal (i.e.: 2015)
Month = 1 to 12
(January to
December)
Day = 1 to 31
—
No
120002 Sets the time of the
internal real-time
clock.
Hour = 0 to 23
Minute = 0 to 59
Sec = 0 to 59
—
No
200001 Sets the current
local display group
or advances to next
display group.
0 = Advance to Next
Display Group
1 – 32 = Set Display
Group
—
—
—
No
500000 Change the state of
continuous triggering
for Triggered Archive
if Triggered Archive is
in manual mode. The
trigger interval is fixed
at one second.
0 = Stop triggering
1 = Start triggering
—
—
—
No
500001 Sets archive trigger
once if triggered
archive is in manual
mode.
—
—
—
—
No
500002 Releases a triggered
archive from a
latched state.
—
—
—
—
No
500050 Publishes all
triggered registers to
the previous triggered
registers.
—
—
—
—
No
500100 Creates archive
partial records.
—
—
—
—
No
500300 Clears the
unacknowledged
device alarms. Will
not unlatch DIO.
—
—
—
—
No
500500 Bit mask uses bits to
identify which DIO
blocks to clear.
Bit Mask:
XXXX XXXX XX65 4321
0 = Do Not Unlatch DIO
1 = Unlatch DIO
—
—
—
No
500600 Enables wireless
manager.
—
—
—
—
No
500601 Disables wireless
manager.
—
—
—
—
No
12
Section 1
Scanner 3100 Modbus Protocol