Fluid Status Definitions
Bit Position
Fluid Status When Bit=1
0
Fluid Change
1
No Temperature Change
2
No Pressure Change
3
Ideal Properties Incorrect
4
Molar Mass Incorrect
5
Ideal Absolute Viscosity Incorrect
6
Base Density Incorrect
7
Gas to Liquid Volume Ratio Incorrect
8
Liquid Oil Mass Fraction Incorrect
9
Normal Viscosity Incorrect
10
Flowing Density Incorrect
11
Flowing Viscosity Incorrect
12
—
13
Isentropic Exponent Incorrect
14
Joule Thompson Coefficient Incorrect
15
Enthalphy Incorrect
16
Molar Heating Value Incorrect
17
Mass Heating Value Incorrect
18
Volume Heating Value Incorrect
19
Phase Is Liquid
20
Liquid Oil Density Incorrect
21
Liquid Water Density Incorrect
22
BS&W Value Incorrect
23
—
24
Temperature Range Error
25
Pressure Range Error
26
Thermal Expansion Range Error
27
Density Range Error
28 – 29
—
30
Non-Fatal Convergence Error
31
Configuration Error
Flow Status Definitions
Bit Position
Flow Status When Bit=1
0
Square Root Differential Pressure Incorrect
1
Stability Warning
2
D Material Invalid
3
D Alpha Override Invalid
4
D Corrected Diameter Invalid
131
Scanner 3100 Modbus Protocol
Section 2