Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7707
1E1B
FR2: HFluid: Net Volume Combustion Heating Value
FP
MMBtu/ft³
RO
7708
1E1C
FR2: HFluid: Wobbe Index
FP
—
RO
7709
1E1D
FR2: HFluid: Motor Octane Number Linear
FP
—
RO
7710
1E1E
FR2: HFluid: Motor Octane Number CARB
FP
—
RO
7711
1E1F
FR2: HFluid: Methane Number Linear
FP
—
RO
7712
1E20
FR2: HFluid: Methane Number CARB
FP
—
RO
7713
1E21
FR2: HFluid: Heat Of Vaporization Of Water
FP
Btu
RO
7714
1E22
FR2: HFluid: Enthalpy Change Of Vapor Water
FP
Btu
RO
7715
1E23
FR2: HFluid: Enthalpy Change Of Liquid Water
FP
Btu
RO
7716
1E24
FR2: HFluid: Isentropic Exponent
FP
—
RO
7717
1E25
FR2: HFluid: Joule Thompson Coefficient
FP
—
RO
7718
1E26
FR2: HFluid: Enthalpy Composite
FP
MMBtu/lbm
RO
7719
1E27
FR2: HFluid: Gross CH Pseudocomponent
FP
—
RO
7720
1E28
FR2: HFluid: Gross Carbon Dioxide
FP
—
RO
7721
1E29
FR2: HFluid: Gross Nitrogen
FP
—
RO
7722
1E2A
FR2: HFluid: Gross Carbon Monoxide
FP
—
RO
7723
1E2B
FR2: HFluid: Gross Hydrogen
FP
—
RO
7724
1E2C
FR2: HFluid: Gross Specific Gravity
FP
—
RO
7725
1E2D
FR2: HFluid: Liquid Base Viscosity
FP
lbm/ft·s
RO
7726
1E2E
FR2: HFluid: Liquid Flowing Viscosity
FP
lbm/ft·s
RO
7727
1E2F
FR2: HFluid: Liquid Alpha
FP
1/°F
RO
7728
1E30
FR2: HFluid: Liquid Equilibrium Vapor Pressure
FP
psia
RO
7729
1E31
FR2: HFluid: Correction For Temperature On Liquid
FP
—
RO
7730
1E32
FR2: HFluid: Correction For Pressure On Liquid
FP
—
RO
7731
1E33
FR2: HFluid: Composite Correction On Liquid
FP
—
RO
7732
1E34
FR2: HFluid: Gas To Liquid Volume Ratio
FP
—
RO
7733
1E35
FR2: HFluid: Liquid Oil Mass Fraction
FP
—
RO
7734
1E36
FR2: HFluid: Liquid Shrinkage Factor
FP
—
RO
7735
1E37
FR2: HFluid: Liquid BSW
FP
%
RO
7736
1E38
FR2: HFluid: Liquid Oil Base Density
FP
lbm/ft³
RO
7737
1E39
FR2: HFluid: Liquid Oil Flowing Density
FP
lbm/ft³
RO
7738
1E3A
FR2: HFluid: Liquid Water Base Density
FP
lbm/ft³
RO
7739
1E3B
FR2: HFluid: Liquid Water Flowing Density
FP
lbm/ft³
RO
7740
1E3C
FR2: HFluid: Liquid Composite Flowing Density
FP
lbm/ft³
RO
7741
1E3D
FR2: HFlow: Reference Orifice Diameter
FP
inch
RO
7742
1E3E
FR2: HFlow: Reference Meter Tube Inside Diameter
FP
inch
RO
7743
1E3F
FR2: HFlow: Reference Orifice Temperature
FP
°F
RO
7744
1E40
FR2: HFlow: Reference Meter Tube Temperature
FP
°F
RO
7745
1E41
FR2: HFlow: Orifice Alpha
FP
1/°F
RO
54
Section 1
Scanner 3100 Modbus Protocol