Slave 2 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7051
1B8B
Slave Device 2: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
7053
1B8D
Slave Device 2: Flow Run Config: Carbon Dioxide
FP
—
RW
7055
1B8F
Slave Device 2: Flow Run Config: Nitrogen
FP
—
RW
7057
1B91
Slave Device 2: Flow Run Config: Specific Gravity
FP
—
RW
7059
1B93
Slave Device 2: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
7061
1B95
Slave Device 2: Flow Run Config: Oil Density
FP
lbm/ft³
RW
7063
1B97
Slave Device 2: Flow Run Config: Gas Fraction
FP
—
RW
7065
1B99
Slave Device 2: Flow Run Config: Plate Diameter
FP
inch
RW
7067
1B9B
Slave Device 2: Flow Run Config: Pipe Diameter
FP
inch
RW
7069
1B9D
Slave Device 2: Flow Run Config: Cone Beta
FP
—
RW
7071
1B9F
Slave Device 2: Flow Run Config: Nominal Value
FP
—
RW
7073
1BA1
Slave Device 2: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
7075
1BA3
Slave Device 2: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 3 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7101
1BBD
Slave Device 3: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
7103
1BBF
Slave Device 3: Flow Run Config: Carbon Dioxide
FP
—
RW
7105
1BC1
Slave Device 3: Flow Run Config: Nitrogen
FP
—
RW
7107
1BC3
Slave Device 3: Flow Run Config: Specific Gravity
FP
—
RW
7109
1BC5
Slave Device 3: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
7111
1BC7
Slave Device 3: Flow Run Config: Oil Density
FP
lbm/ft³
RW
7113
1BC9
Slave Device 3: Flow Run Config: Gas Fraction
FP
—
RW
7115
1BCB
Slave Device 3: Flow Run Config: Plate Diameter
FP
inch
RW
7117
1BCD
Slave Device 3: Flow Run Config: Pipe Diameter
FP
inch
RW
7119
1BCF
Slave Device 3: Flow Run Config: Cone Beta
FP
—
RW
7121
1BD1
Slave Device 3: Flow Run Config: Nominal Value
FP
—
RW
7123
1BD3
Slave Device 3: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
7125
1BD5
Slave Device 3: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 4 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7151
1BEF
Slave Device 4: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
7153
1BF1
Slave Device 4: Flow Run Config: Carbon Dioxide
FP
—
RW
7155
1BF3
Slave Device 4: Flow Run Config: Nitrogen
FP
—
RW
166
Section 2
Scanner 3100 Modbus Protocol