Random value details
20.3.36.1
Behaviour
The module outputs random values from a specific value range on the
Output 0
. This can occur
cyclically or upon receipt of the value 1 (logical "true") on
Input 0
.
The data type of the
Input 0
is Boolean. If necessary, incoming values are converted before the
calculation (see conversion table below).
20.3.36.2
Extended settings
Via the
Internal data type
parameter, you can specify the internal data type of
the module. The data type of the random values to be output is also defined by
this.
Via the
Cycle time
parameter, you can specify in which intervals (seconds) ran-
dom values shall be sent. Deactivate the associated control field if the values
are not to be sent out cyclically.
Via the
Lower limit
and
Upper limit
parameters, you can specify the value range
from which the random values shall originate.
Via the
Only send with change
parameter, you can specify whether an output
value shall only be sent if the result of the calculation is different to the previ-
ously calculated result.
20.3.36.3
Conversion table
Boolean
(converted)
Boolean ---
Number
0
≠
0
→
→
true
false
DPTTime true
DPTDate true
Summary of Contents for Busch-ComfortTouch
Page 1: ...Product manual Busch ComfortTouch Busch ComfortTouch www BUSCH JAEGER de ...
Page 16: ...16 240 ...
Page 147: ...147 240 03_03_09_00_EN html Logikbausteine ...
Page 155: ...155 240 03_03_09_00_EN html Logikbausteine 03_03_09_00_EN html Boolean ...
Page 217: ...217 240 03_03_09_00_EN html weitere_math 03_03_09_00_EN html weitere_math ...
Page 226: ...226 240 03_03_09_00_EN html Signalkontrolle ...