77
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
System cable
The D45 system only works correctly if CAT5 original cables are used . Twisted pairs offer good standard and differential
immunity . The CAT5 cable must have a resistance value of 180 ohm/km ( for every twisted pair) .
Tia/eia
caTegory
iso/iec
class
ansi/Tia/eia
sTandard
iso/iec
sTandard
Frequency
Mhz
coMMon ieee or Tia/eia applicaTions
CAT5
D
568-A
11801:1999
100
802.5 - Token Ring
802.3 - 10BASE-T Ethernet
802.3 - 100BASE-T Ethernet
CAT5e
D
568-B
11801:2002
100
802.5 - Token Ring
802.3 - 10BASE-T Ethernet
802.3 - 100BASE-T Ethernet
802.3 - 1000BASE-T Ethernet
BTicino recommend the use of its cable CAT 5 .
Details as follows:
caT.5e u/uTp cables
U/UTP
SHEATH
LENGTH
PACKAGING
032750
LSZH
305 m
BOX
032751
PVC
305 m
BOX
032873
LSZH
1000 m
COIL
032874
PVC
1000 m
COIL
Unshielded U/UTP cat . 5e cables with solid copper 24AWG
(0 .51 mm) conductors, polyolefin insulation, 4 twisted pair
with internal separator – in accordance with ISO/IEC 11801 e
2 .0, EN 50173-1 e EIA/TIA 568 B2 . 10 standard – colour grey .