RA-1000 Series

Remote Multiplex Annunciator Panels

LT-617 Rev. 13
November 29  2006

Installation and Wiring Manual

Advanced Life Safety Solutions

Advanced Life Safety Solutions

Summary of Contents for RA-1000 Series

Page 1: ...RA 1000 Series Remote Multiplex Annunciator Panels LT 617 Rev 13 November 29 2006 Installation and Wiring Manual Advanced Life Safety Solutions ...

Page 2: ......

Page 3: ...l i Contents Introduction 1 Technical Support 1 Installation Instructions 2 Wiring Instructions 3 DIP Switch Settings 4 Specifications and Features 7 Enclosure Models 7 Module Models 7 Current Drain for Battery Calculations 8 Warranty Warning Information 9 ...

Page 4: ...Contents ii ...

Page 5: ...ciator Chassis is a 16 circuit non expandable annunciator The RAM 1016TZ is the same as the RAM 1016 with 16 added zoned trouble LEDs The RAX 1048TZ is the same as the RAX 1048 with 48 added zoned trouble LEDs Each circuit indicator is a bi colour LED that is automatically configured to match the fire alarm control panel configuration There are five types of enclosures available the BB 1001 BB 100...

Page 6: ...bel sheet BACKBOX HEIGHT H MOUNTING A IN MOUNTING B IN BB 1001 9 0 9 95 7 5 BB 1002 18 0 9 95 16 5 BB 1003 26 5 9 95 24 9 BB 1008 33 0 20 9 35 2 BB 1012 45 0 20 9 52 0 Note The RA 1000 normally displays Initiating Circuit Status no individual circuit troubles however models RAM 1016TZ RAM 1032TZ and RAX 1048TZ will allow individual circuit trouble indication Indicating and Relay Circuits are not r...

Page 7: ...culate the maximum current for all annunciators summed together Note All circuits are power limited and must use type FPL FPLR or FPLP power limited cable ATTENTION Accidentally connecting any of the 24 VDC wires to the RS 485 wiring will result in damage to the annunciator and or to the fire alarm control panel to which it is connected Max for all Annunciators Maximum Wiring Run to Last Annunciat...

Page 8: ...isable Fire Drill button SW1 3 Address A2 SW2 3 Disable Acknowledge button SW1 4 Address A3 SW2 4 Disable General Alarm button SW1 5 Must be set to OFF when used with FA 1000 FA 300 and FA 200 Series SW2 5 Not Used SW1 6 Not Used SW2 6 Disable Auxiliary Disconnect button SW1 7 Not Used SW2 7 Not Used SW1 8 Checksum Select SW2 8 Disable Signal Silence button DIP Switch Positions Annunciator Address...

Page 9: ...FF ON 35 ON ON OFF OFF OFF 51 ON ON OFF OFF ON 36 OFF OFF ON OFF OFF 52 OFF OFF ON OFF ON 37 ON OFF ON OFF OFF 53 ON OFF ON OFF ON 38 OFF ON ON OFF OFF 54 OFF ON ON OFF ON 39 ON ON ON OFF OFF 55 ON ON ON OFF ON 40 OFF OFF OFF ON OFF 56 OFF OFF OFF ON ON 41 ON OFF OFF ON OFF 57 ON OFF OFF ON ON 42 OFF ON OFF ON OFF 58 OFF ON OFF ON ON 43 ON ON OFF ON OFF 59 ON ON OFF ON ON 44 OFF OFF ON ON OFF 60 O...

Page 10: ...s on page 3 for details SW1 SW2 Set DIP Switches as described in DIP Switch Settings on page 4 JW6 RS 485 termination jumper Remove on all except for last RAM 1032 TZ On the RAM 1016 TZ Main Annunciator Chassis P2 Not used No expansion allowed P3 P11 Not used Jumpers Factory set Do not change Terminals See Wiring Instructions on page 3 for details SW1 SW2 Set DIP Switches as described in DIP Switc...

Page 11: ...up to 32 points with trouble annunciation on the TZ version Expandable by using up to four RAX modules Standby 50 mA Max All LEDs On 150 mA Max TZ version Standby 50mA Max All LEDs On 300mA Max RAM 1016 TZ Main Annunciator Chassis 16 Display Points TZ version has 16 extra trouble displays 20 to 39 VDC filtered or full wave rectified Sealed membrane like buttons and LED indicators Local Buzzer Indi...

Page 12: ...attery Calculations The lamp test feature draws the maximum normal current because it illuminates all lamps on one chassis at a time Thus the currents are Normal Standby Current 50 mA ______________ X 15 mA _________ number of adder chassis Maximum 150 mA ______________ X 15 mA _________ number of adder chassis Use the Normal Standby Current for battery size calculations see the fire alarm control...

Page 13: ...ies it is possible for the batteries to fail Even if the batteries have not failed they must be fully charged in good condition and installed correctly If a device operates only by AC power any interruption however brief will render that device inoperative while it does not have power Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipm...

Page 14: ...avoid injury or death Alarm Notification Appliances Alarm Notification Appliances such as sirens bells horns or strobes may not warn people or waken someone sleeping if there is an intervening wall or door If notification appliances are located on a different level of the residence or premise then it is less likely that the occupants will be alerted or awakened Audible notification appliances may ...

Page 15: ...r must promptly notify Mircom Technologies Ltd in writing that there is defect in material or workmanship such written notice to be received in all events prior to expiration of the warranty period International Warranty The warranty for international customers is the same as for any customer within Canada and the United States with the exception that Mircom Technologies Ltd shall not be responsib...

Page 16: ...ogies Ltd will at its option repair or replace out of warranty products which are returned to its factory according to the following conditions Anyone returning goods to Mircom Technologies Ltd must first obtain an authorization number Mircom Technologies Ltd will not accept any shipment whatsoever for which prior authorization has not been obtained Products which Mircom Technologies Ltd determine...

Page 17: ......

Page 18: ...Notes ...

Page 19: ......

Page 20: ...3 Tel 905 660 4655 Fax 905 660 4113 Mircom 2006 Printed in Canada Subject to change without prior notice www mircom com Advanced Life Safety Solutions U S A 60 Industrial Parkway PMB 278 Cheektowaga NY 14227 Tel 1 888 660 4655 Fax 1 888 660 4113 ...

Reviews: