19
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
timing
The longest time the handset can be in operation before
picking up the receiver or answering the call is 30 s, after this
time the handset automatically switches to standby mode .
The longest time the handset can be in operation after
picking up the receiver or answering the call is 60 s . After this
time the handset automatically switches to standby mode .
mutual ring control
If several handsets are installed inside an apartment, when
a call is received and answered from one of the handsets, all
the other handsets will stop ringing .
vDp priority
When the handset is monitoring a riser EP, if there is a call
from the EP, Switchboard or a Small EP, the handset will
stop monitoring and will respond to the call . When the
handset is communicating with a Small EP, and there is a
call from the EP or the MC, the handset will stop the current
communication and respond to the call . When the handset
is communicating with other internal handsets, and there is
call from the EP, MC or Small EP, the handset will stop the
current communication and respond to the call .
Door lock release
When this device and the EP are in operation, press the door
lock release pushbutton to release the lock controlled by the
EP . When this device and the Small EP are working, press the
door lock release pushbutton to release the lock controlled
by the Small EP .
Alarm
type oF alarm
Anti-removal alarm, SOS alarm, and zone alarm are three
types of alarms .
anti-removal alarm
Anti-removal alarm: when the handset’s burglar alarm and
the zone alarm are enabled, if the Handset is removed, an
anti-removal alarm message will be sent to the Switchboard .
If the anti-removal switch is connected to the alarm sensor,
when the alarm sensor is dismantled, the handset will also
send anti-removal alarm message to Switchboard .
Note: don’t dismantle the handset and the alarm sensor if you use the alarm function.
Burglar alarm zone are zone 1, zone 2, zone 5, zone 6, zone 7, zone 8; Fire alarm zones
are zone 3 and zone 4.
sos alarm
SOS pushbutton on the panel
The SOS alarm message will be sent to Switchboard by
pressing SOS button .
External SOS alarm
The SOS alarm message will be sent to Switchboard by
pressing external SOS key . For the setting method, please
refer to the “Installation setting operation list” table . The
default status of the external SOS is always NO .
alarm operation anD alarm senDing
Alarm zone connectors
This device has 8 external sensor connectors . A professional
installer is required to install the alarm sensors and setup the
software . Burglar alarm zones are zone 1, zone 2, zone 5, zone 6,
zone 7, zone 8; Fire alarm zones are zone 3 and zone 4 .
Enabling alarm zones
The user can enable alarm zones with the user password .
For the details of the operation please refer to the table
“Functional list for setting and channelling alarms” . Once
the setup operation has been completed, the alarms for
which the zones have been enabled will flash slowly . After
the time delay has expired (for burglar alarm zones, the
default delay time is 100 s; for fire alarm zones it is 2 s . A
professional installer is required to change the time delay),
once the sensors are active, they will monitor the situation
and send an alarm signal if needed .
Sending alarms
When the sensors are active, if any alarm situation occurs,
the corresponding alarm zone lights will flash quickly .
Meanwhile, a beep will also be emitted for fire alarm zones .
For burglar alarms the beep will be emitted if the system has
been set to do so during installation .
Sending and cancelling alarm messages
When an alarm situation occur, if the alarm is not cancelled
during the set time (default time is 40 s), the alarm message
will be sent to Switchboard . When an alarm occurs, user can
cancel the alarm with the user password . Once the alarm has
been cancelled, it will not be sent to Switchboard .
Disabling alarm zone
Users can disable alarm zones with the user password .
For the operation details please refer to the table “List of
operations to enable and disable alarm zones” .
Installation and inspection
The installer should test the alarm function by simulating an
alarm after the parameters have been set and the hardware
has been installed, in order to ensure that they are correct .