SONORA -
CARATTERISTICHE GENERALI
50
VIDEO DOOR ENTRY SYSTEM -
GENERAL FEATURES
D45
District generator
323013 - District generator
323013 is the district hub that can be connected with 4
district riser shunts, 1 wall EP connector, 1 Switchboard
connector and 1 main system power connector . It’s used
to create large networks . Can be connected in cascade to
extend to 16 district branches . The maximum level of cascade
connection is 1 . When installed as part of the system, the
device controls and changes video channel, and provides
amplifying compensation for video signal . The video gains
of each Riser shunt district branch can be set separately .
legenD
1 . POWER: Input connector main system power supply
2 . POWER: Input connector main system power supply
3 . Switchboard: Connector for Switchboard
4 . Main EP: Connector for wall EP
5 . D1: Riser shunt branch 1
6 . D2: Riser shunt branch 2
7 . D3: Riser shunt branch 3
8 . D4: Riser shunt branch 4
9 . Configurators socket
10 . Adjust switch for branch 2 video gain
11 . Adjust switch for branch 1 video gain
12 . Adjust switch for branch 4 video gain
13 . Adjust switch for branch 3 video gain
14 . Serial interface connector for upgrading the software
and connecting the PC
15 . Adjust switch for WEP or message release to indoor unit
channel video gain
16 . CFG: Indicator light for configuration by pushbutton
17 . S2 Key
18 . S1 Key
19 . POWER: Indicator light
15
18
16
19
17
2
4
1
5
9
7
11 12
6
10
13
14
8
3
System accessories functions overview