![background image](http://html.mh-extra.com/html/bticino/d45/d45_technical-manual_2825385115.webp)
113
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
323005 - power supply conFiguration
possible conFiguration way For power supply
Mode 1
Mode 2
Resistor configuration
√
√
Keyboard configuration
√
√
RS232 configuration
√
√
meaning oF each conFigurator socket pin
conFiguraTion Mode 1
(1 pws For each Floor)
Mode 2
N
NNN
NNN
N
N
CF4
FF Min
FF Min
CF5
CF6
#II
CF7
CF8
FF Max
FF Max
CF9
CF10
CF11
Type
Type
Type
ASR
ASR
ASR
M
M
M
LE
LE
LE
conFigurators position For power supply
N
N
N CF4 CF5 CF6 CF7
N
N
N
FF
min
FF
min
#I
#I
CF8 CF9 CF10CF11 TYP ASR M
LE
FF
max
FF
max
TYP ASR M
LE
NNN
: Power supply address (range 1–256), only when
TYP=1, the power supply address will be valid . It means
when TYP=0, there is no need to configure NNN .
FF Min: the floor number where this power management
starts from .
FF Max
: the floor number where this power management
ends . FF Max must over or equal to FF Min .
#II: number of apartments on each floor (at mode 1, the
default number is 4, no need to set)
#Min handset
: the address of the first address managed by
this power supply)
#Max handset
: the last handset address managed by this
Power supply)
TYP
: configuration position for the power supply function .
Used to enable or disable the power supply management
function and the smart power function .
ASR
: set how much current the power supply will offer to
each handset for the alarm function .
M
: position to choose configuration mode . connecting
configurator 0 means choosing mode 1 or mode 2 .
LE
: configuration position for smart power supply
management . Only valid when TYP=1 . When TYP=0, no
need to configure that position .