7
D
45
VIDEO
DOOR
ENTR
Y SY
STEM
call transFer
In case that the entry panel is used as (Riser EP or secondary
EP), visitors or residents can call the Switchboard from
the entrance panel and ask to be put through to a certain
handset . The Switchboard will then call the handset and
after hanging up, direct communication between the
entrance panel and the handset will be established .
open the locks by passworD
As per the prompt on the display, we can input the unlock
password after pressing on the # key . By pressing the same
key again, the electric lock will be opened automatically .
If the password input is not correct, the display will show
“wrong password” and return to idle after three short beeps .
Now press on the # key and re-input the password .
Note: If the unlock function is disabled, it will fail. When starting this function,
therefore refer to the setting.
alarm For overtime Door opening
When the lock-status signal type has been correctly
set, and the riser door is open for over 120 seconds, the
corresponding entrance panel will send an alarm to the
Switchboard .
Note: This function requires that the electric door lock on the entrance panel is fitted
with a lock-status (open and close) signal output, and it will only work when the
lock-status signal is connected to the DAS in the 7P wiring port behind the entrance
panel.
alarm For the Distress coDe
When the six-digit user password is entered for unlocking,
and if the user re-enter the distress code “5” and presses the
key for confirmation, then the entry panel shall send the
distress code alarm to the Switchboard while it opens the
lock .
Recover the master password:
When the entrance panel is at standby, press the reset
switch at the back of the entrance panel for more than 5
seconds . A long beep will be heard and the password will
be reset to 200000 .
Summary of Contents for D45
Page 1: ...D45 System technical guide TECHNICAL GUIDE 2011 D45 Release 01 September 2011 ...
Page 2: ......
Page 128: ......
Page 138: ......
Page 155: ......