No PC support is needed/useful for these activities .
Using this configuration only the default apartment
functions are available .
With the simple configuration maximum 4000 apartments
can be installed:
40 riser shunts (unit/riser)
25 floors
4 handsets/floor
Alternatively we can have:
16 riser shunts (unit/riser)
40 floors
6 handsets/floor
25 riser shunts (unit/riser)
40 floors
4 handsets/floor
22 riser shunts (unit/riser)
30 floors
6 handsets/floor
20 riser shunts (unit/riser)
25 floor s
8 handsets/floor
or others …] .
The simplified configuration can be applied to a standard
installation or to a district of a multichannel installation
inheriting the limits of the chosen configuration type .
Flexible conFiguration
Before configuring the system two numbers must be
decided:
#FF maximum number of floors of the units/risers of the
installation .
(a two digit number typical of the installation– max
value 99) .
#I I maximum number of apartments of the floors in the
installation .
(a two digit number typical of the installation – max
value 99) .
It is compulsory to configure:
1 . Audio/video doorphone handsets . For each handset, its
F F I I address code must be configured, starting from
flat number 1 and from floor number 1 and the typical
installation #ii number .
2 . Riser shunt . each riser shunt must be configured
progressively staring from 1 and the and the typical
installation #ii number .
3 . Wall entrance panel and Switchboard . In each wall
entrance panel and Switchboard, the #FF and #ii
installation numbers must be configured .
If in the entrance panel or Switchboard the progressive riser
shunt address is used as the lowest two digits of DDDD, no
configuration of the apartment/villa to call is needed in the
Wall entrance panel or Switchboard . If the customer want
a complete DDDD address to call the apartment/villa, an
association must be performed on the wall entrance panel
and on the Switchboard between the riser shunt progressive
address and the DDDD requested by the user . Using this
configuration only the default apartment functions are
available .
A PC is not needed to configure the system on the installation - it
can be used during the project phase to easily identify and check
if it is possible to configure the system following the flexible
configuration method – it is an alternative to the table below .
The flexible configuration can be used in installation of up
to 4000 apartments, with the maximum limits listed in the
linked table
(that can be shared with the people in charge
of the configuration – and can be completed using how
much row we want to communicate) .
NUMBERS
oF RISER SHUNTS
NUMBERS
oF FLooRS
# FF
NUMBERS
oF FLATS/FLooR
#II
NUMBER oF
APART. IN EAcH
UNIT/RISER
99
10
4
40
20
50
4
200
11
90
4
360
66
10
6
60
13
50
6
300
7
90
6
540
50
10
8
80
10
50
8
400
5
90
8
720
25
10
16
160
5
50
16
800
12
10
32
320
6
20
32
640
The simplified configuration can be applied to a simplified
installation or to a district of the complete installation,
inheriting the limits of the chosen configuration type .
DeFault behaviour oF apartment Functions
The default functions are available both with simplified and
flexible system configuration .
The default functions are:
n
Self-powering of the main riser EP;
n
Repeated pression on self power on function changes on
next address riser EP;
n
Call to Switchboard is to main Switchboard;
n
Alarm collected by main Switchboard .