Confidential
2-63
All single color
Random color
User Check
- Check that ink cartridge is loaded correctly.
Step
Cause
Solution
1
Carriage PCB defective
Replace the carriage PCB ASSY.
2
Head defective
Replace the head/carriage unit.
3
Main PCB defective
Replace the main PCB ASSY.
User Check
- Check that ink cartridge is loaded correctly.
- Carry out head cleaning.
Step
Cause
Solution
1
Maintenance unit stained
Clean the maintenance unit (refer to
2
Wrong head property value
Input the head property value (refer to
5, Section 1.3.25 "Updating of Head Property
Data and Backup/Restoration of Head
Calibration Data."
3
Head calibration uncompleted
Write the head calibration data (refer to
5, Section 1.3.2 "Creating of Head Calibration
Data and Writing it into Flash ROM."
4
Non-discharge of ink from
head
Perform the recommended purge procedures.
(refer to the recommended procedures in
Chapter 5, Section 1.3.29 "Purge Operation
(Maintenance mode 76)"
5
Carriage PCB defective
Replace the carriage PCB ASSY.
6
Head defective
Replace the head/carriage unit.
7
Main PCB defective
Replace the main PCB ASSY.