4-5
Confidential
1.4
Initialize the EEPROM parameters (Maintenance mode 01)
Initialize the EEPROM parameters, referring to
Chapter 5, Section 1.3.1 "EEPROM
1.5
Restore the head calibration data (Maintenance mode 68)
Restore head calibration data that has been backed up in an external memory,
referring to
Chapter 5, Section 1.3.25 "Updating of Head Property Data and Backup/
Restoration of Head Calibration Data."
If the restoration is successfully completed, the procedure given in
is not required.
1.6
Set the serial number (Maintenance mode 80)
Set the serial number, referring to
Chapter 5, Section 1.3.32 "Display of the
The serial number can also be set with the service setting tool (BrUsbSn.exe) that
enables the head property data to be updated (
Section 1.7 "Update the head property
) at the same time.
The serial number setting procedure is given below.
(1) Turn the machine ON and switch it to the maintenance mode.
(2) Connect the machine to your PC using a USB cable.
(3) On the PC, run the service setting tool (BrUsbSn.exe) to display the following
window.
(4) In
Product Category
, select
1 Ink-Model
.
(5) Select
2013 Model_2
.
Summary of Contents for MFC-J6920DW