Confidential
2-20
Code 1
Code 2
Cause
Refer to
page:
A8
01
Receive RTN or PIN or ERR (sending side.)
Section 4.9.3
"A communications
error occurs"
A9
01
Send RTN or PIN or ERR (receiving side.)
AA
18
Receive buffer full during receiving into memory.
B0
02
Unable to receive the next-page data.
B0
03
Unable to receive polling even during turn-around
transmission due to call reservation.
B0
04
PC interface error
BF
01
Communication canceled by depressing
X
key
before confirming FAX communication.
BF
02
Communication canceled by depressing
X
key after
confirming FAX communication.
C0
01
No common modulation mode or polling failed.
C0
02
Unable to detect JM.
C0
03
Unable to detect CM.
C0
04
Unable to detect CJ.
C0
10
V. 34 negotiation or training not finished.
C0
11
Modem error detected during V. 34 negotiation or
training.
C0
20
Modem error detected during sending of
commands.
C0
21
Modem error detected during receiving of
commands.
C0
22
Control channel connection time-out.
C0
30
Modem error detected during sending of image
signals.
C0
31
Modem error detected during receiving of image
signals.
E0
01
Failed to detect 1,300 Hz signal in burn-in
operation.
E0
02
Failed to detect PB signals in burn-in operation.
E0
03
Command not detected from RS232C in burn-in.
Summary of Contents for MFC-J6920DW
Page 123: ...3 3 Confidential 2 PACKING ...
Page 146: ...3 26 Confidential 3 Set the protective part Protective part ...
Page 308: ...5 37 Confidential pfadj2 Pattern ...
Page 315: ...5 44 Confidential Margin Check Pattern ...
Page 362: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...