3-127
Confidential
9.63 T2 Bank ASSY
(1) Remove the two screws (TAPTITE CUP B M3x8) from the Lower tray frame.
(2) Release the two Hooks and remove the Lower tray frame from the Lower tray unit.
Fig. 3-154
(3) Release the four Hooks and remove the T2 bank ASSY from the Lower tray unit.
Fig. 3-155
TAPTITE CUP B M3x8
TAPTITE CUP B M3x8
Lower tray frame
Lower tray unit
Hooks
Lower tray unit
Hooks
Hook
Hook
Hook
T2 bank ASSY